TM 55-2915-335-30&P
2-10. PUMP AND HOUSING ASSEMBLY - lNSPECT/REPLACE/REPAIR
2-10
This task covers: Removal and installation of the pump cartridge in the housing. It also covers repair of the pump
electrical cable assembly.
INITIAL SETUP
Tools:
Material/Parts:
Aircraft Electricians Tool Kit, NSN 5180-00-323-4915
Cleaning Cloth, Nonwoven, NSN 8305-00-753-2967
Brush, Soft Bristle, Cleaning
Dry Cleaning Solvent, NSN 6850-00-274-5421
Multimeter, NSN 6625-00-168-0585, or equivalent
White Petrolatum, NSN 6505-00-133-8025
Cartridge Pulling Tool (Item 4, Appendix D)
Preformed Packing, 2req, NSN 5330-00-435-9355
Preformed Packing, NSN 5330-00-410-4887
Personnel Required:
68F Aircraft Electrician
NOTE
No inspection or repair of the pump cartridge or housing is covered
in this task. Procedures are limited to removal and installation of the
pump cartridge in the housing and repair of the pump cable as-
sembly. For inspection and repair of either the cartridge or housing,
refer to the applicable maintenance task.
1. CLEANING
Compressed air aimed at the skin can cause serious injury or death.
Wear goggles and never use over 30 psi (207 kPa) of compressed air
for cleaning.
Cleaning solvent can be hazardous to your health. Use solvent only
in well ventilated areas. Avoid breathing solvent vapors. Do not use
solvent near an open flame or other source of high heat. Always wear
gloves, apron, and goggles when using cleaning solvent. Store solvent
in approved metal container only.
a. Wash fuel boost pump (1) in dry cleaning solvent (Item 7, Appendix C). Use soft bristle brush to remove dirt
from recessed areas. Use non-woven cleaning cloth (Item 1, Appendix C) to wash outside surfaces.
GO TO NEXT PAGE
2-21
|