TM 55-2915-335-30&P
2-23. ELECTRICAL CIRCUITS - lNSPECT/REPLACE (Cont)
2-23
Position lead wire on mounting stud as
instructed. Failure to position lead cor-
rectly will cause improper alignment of
the field tube. This could lead to early
pump failure.
(7)
Install a 2-1/4 inch (57 mm) length of shrink
tube (1) over mounting stud and lead wire.
Use 1/4-inch shrink tube (Item 2, Appendix
B, Bulk Items List). Position lead wire exactly
as shown in top view of negative side circuit.
Push shrink tube down to about 1/4 inch
from shrink tube (4). Use heat gun to shrink
lead wire in place on stud.
If reusing secondary brush, do not trim
shunt leads. Brush away used solder and
re-tin lead.
(8) Cut off lead wire (2) even with top of stud
(3). Strip 1/4 inch (6,4 mm) of insulation
from wire end. Cut shunt lead of new brush
(6) to about 7/8 inch (22 mm). Tin ends of
shunt lead and lead wire. Overlap leads 1/4
inch (6,4 mm) and solder. Use rosin-core
solder (Item 8, Appendix C).
NOTE
GO TO NEXT PAGE
2-83
|