MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
If pin is damaged, notify unit maintenance.
4. FILLER/DISCHARGE ASSEMBLY LEAKS.
Step 1. Check for loose filler/discharge coupling connections.
Close coupling lock arms.
Step 2. Check for loose or missing bolts on water tank coupling half.
If bolts are loose or missing, notify unit maintenance.
Section III. OPERATOR MAINTENANCE PROCEDURES
Page
General ..................................................................................................................................................... 3-3
Water Tank Repair .................................................................................................................................... 3-3
3-3. GENERAL.
This section contains procedures for performing operator maintenance on the 20K and 50K Gallon Collapsible Water
Tanks. Operator maintenance is limited to installation of temporary clamp patches and plugs supplied in the tank repair
kit.
3-4. WATER TANK REPAIR.
a. General. Slits, tears or cuts in the water tank smaller than 6 1/2 inches are repaired with sealing clamps. Small
punctures are repaired using the wooden plugs. Damage larger than 6 1/2 inches requires replacement of the
water tank.
b. Emergency Repairs. In emergencies, the wooden plugs supplied in the repair kit may be used to temporarily
seal small holes or punctures to allow continued operation. To install the plugs, proceed as follows:
Repairs with plugs
(1) Select size of plug required.
Hole Size
Plug Size
Up to 1/2-inch
use
3-inch long plug
Up to 1 1/2 inches
use
5-inch long plug
3-3
|