TM 5-5430-210-12 Table  3-2.  Troubleshooting  (con’t) MALFUNCTION TEST OR INSPECTION CORRECTIVE  ACTION 12. CONTROL VALVE ASSEMBLY COUPLING (FEMALE) LEAKS (7, fig. B-4). Step 1. Check the coupling for miming or loose hexagon head cap screws (4 and 5). Replace all missing screws and nuts. Tighten all screws and nuts to 30 inch-pounds. Step 2. Check the round flange gasket (8) for damage or breaks, Replace the flanged coupling and replace the gasket (para. 3-9). 13. CONTROL VALVE ASSEMBLY ADAPTER (MALE) LEAKS (12, fig. B-4). Step 1. Check the adapter for miming or lame hexagon head cap nut and screws (9 & 10). Replace all missing screws and nuts. Tighten all screws and nuts to 30 inch-pounds. Step 2. Check the round flanged gasket (13) for damage or breaks. Remove the flanged adapter and replace the gasket (para. 3-9). 14. CONTROL VALVE LEAKS Step 1. Check for loose or missing screws (6, fig. B-5) on the valve bonnet (8). Tighten or replace missing washers and bolts (para. 3-10). Step 2. Check for damaged or distorted bonnet gasket (9). Replace  bonnet  gasket  (para.  3-10) Step 3. Check for bent or distorted bonnet stem (12). Replace  bonnet  stem  (para.  3-10). Section   IV. M A I N T E N A N CE 3-5.  General.  This  section  contains  maintenance and repair instructions for the four collapsible POL tanks. 3-6. Vent Assembly (All Tanks). a. Disassembly. (1)  Disconnect   the   female   quick   disconnect coupling,  (1,  fig.  B-1)  from  the  flanged  male  quick disconnect coupling (4) by pulling outward on cam- lever arms, then lift quick disconnect coupling from the male coupling. (2) Remove  the  eight  screws  and  washers  (2 and 3). Lift flanged coupling (4) from tank fitting. (3) Remove  the  preformed  packing  (5)  from the packing groove in the tank fitting, (4) Separate relief cap (6) from the vent pipe (9) by turning the cap in a counter clock-wise direc- tion until threads disengage. (5) Remove relief cap gasket (7) from the in- side of the relief cap. (6) Turn flame arrestor (8) in a counter clock- wise direction until the threads disengage from the relief cap (6). (7)  To  remove  vent  pipe  (9)  from  the  quick PROCEDURES   (ALL   TANKS) disconnect  coupling  (1),  turn  the  vent  pipe  in  a counterclockwise direction until threads disengage. (8) Remove  dust  cap  gasket  (11)  from  inside of the dust cap (12). b. Cleaning and Inspection. W A R N I N G Drycleaning solvent, P-D-680, used to clean parts is potentially dangerous to personnel   and   property,   Avoid   re- peated  and  prolonged  skin  contact. Do not use near open flame or exces- sive heat. Flash point of solvent is 100 degrees F -138 degrees F (38 degrees C -59 degrees C). (1)  Clean  all  parts  with  cleaning  solvent (Item 1, App. F) and dry thoroughly. (2) Clean out preformed packing grooves thor- oughly. (3)  Inspect  all  mechanical  parts  for  cracks, dents,  breaks,  or  wear.  Replace  or  repair,  if  un- serviceable. (4) Carefully inspect gaskets and packings for deterioration, -distortion, cracks, or breaks. Replace 3-6

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business