TM  5-5430-210-12 Table 3-2. Troubleshooting (con’t) MALFUNCTION TEST OR INSPECTION CORRECTIVE  ACTION 4. FILLER AND DISCHARGE ASSEMBLY LEAKS BETWEEN OVAL CLOSURE PLATE (5, fig. B-2) AND  TANK  FITTING Step 1. Check for missing or loose hexagon head cap screws (3, fig. B-2. Replace all missing screws and washers. Tighten all screws to  30 inch-pounds. Step 2. Check the preformed packing (6, fig. B-2) between the oval closure plate and the tank fitting for nicks, breaks, and com- pression. Replace the packing (para. 3-7). 5. FILLER AND DISCHARGE ASSEMBLY LEAKS BETWEEN OVAL CLOSURE PLATE 5 fig. B-2) AND FLANGED ADAPTER (11). Step 1. Check for missing or loose hexagon head cap screws (7). Replace all missing screws and washers. Tighten all screws to 30 inch-pounds. Step 2. Check the round flange gasket (12) for damage or breaks. Remove the flanged adapter and replace the gasket. (para. 3-7). 6.  FILLER  AND  DISCHARGE  ASSEMBLY  LEAKS  BETWEEN  FLANGED  ADAPTER  (11,  fig.  B-2) AND QUICK DISCONNECT FITTINGS (15). Remove the quick disconnect fittings and check the gaskets (2 & 14) for damage or breaks. Replace the gaskets as required (para. 3-7). 7. FILLER AND DISCHARGE ASSEMBLY LEAKS THROUGH HARDWARE (1, 11 & 15, fig. B-2) OR WILL NOT ASSEMBLE. Check the hardware for cracks, damage and wear. Replace the required hardware (para. 3-7). 8. DRAIN ASSEMBLY LEAKS BETWEEN DRAIN FITTING (3, fig. B-3) AND TANK FITTING (Ex- cluding  Tank  NSN  5430-00-268-8187). Step 1. Check  for  missing  or  loose  hexagon  head  capscrews  (l). Replace all missing screws and washers. Tighten all screws to 30 inch-pounds. Step 2.  Check  the  preformed  packing  (4)  between  the  drain  fitting  (3)  and  the  tank  metal  face  for  nicks,  breaks,  and  com- pression. Replace the packing. (para. 3-8) 9. DRAIN FITTING (3, fig. B-3) LEAKS THROUGH METAL (Excluding Tank NSN 5430-00-268-8187) Check the drain fitting for damage or cracks. Replace the drain fitting (para. 3-8. 10. DRAIN CONTROL VALVE LEAKS (5, fig. B-3). Step 1. Check to ensure that the control valve is closed completely. Close  control  valve. Step 2. If completely closing the control valve does not stop the leakage, check for damage or wear. Replace the control valve (para. 3-8). 11. HOSE ASSEMBLY COUPLING LEAKS (2, fig. B-4) Step 1. Check the coupling gaskets (1 & 3) for damage or wear. Replace the gaskets Step 2. Check the quick disconnect coupling and adapter attached to the hose for dir& damage, or wear. Remove dirt or any foreign objects found inside of the couplings. If this fails to correct the leakage, re- place the hose assembly (para. 3-9). 3-5

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business