TM5-4930-235-13&P
WARNING
End cap is under spring tension. Remove capscrews slowly to prevent parts from flying out.
Failure to comply can result in personal injury.
(b) Loosen capscrews (2). Push down on end cap (3) and remove capscrews (2) from end cap (3).
(c) Slowly release end cap (3) to relieve spring tension.
(d) Remove end cap (3), springs (4 and 5), and indicator shaft (6) from nozzle body (47).
NOTE
Do not remove retaining ring from indicator shaft unless inspection indicates replacement is required.
(e) Remove spring (5), flat washer (8) and retaining ring (7) from indicator shaft (6).
(9) Remove piston (9) as follows: (See Figure 5-4. )
(a) Align pins in piston torque tool with holes in flange of piston (9, Figure 5-2).
(b) Turn piston torque tool counterclockwise to loosen piston (9) from stem (21).
(c) Remove piston torque tool and piston (9) from nozzle body (47).
(10) Remove hinge pins (10) from sides of handle (11).
(11) Remove handle (11) and washers (12) from nozzle body (47).
CAUTION
Do not disassemble handle unless inspection shows that replacement is required. Only remove
parts requiring replacement.
(12) Disassemble handle (11) and related parts as follows:
(a) Drive spring pin (13) from handle (11).
(b) Remove thumb latch (15) and spring (16) from groove in handle (11).
(c) Drive dowel pin (14) out of thumb latch (15) from outside surface.
(d) Drive dowel pins (17) out of handle (11).
(13) Remove stem guide (18) as follows:
(a) Align pins in piston torque tool with holes in flange of stem guide (18).
(b) Turn piston torque tool counterclockwise to loosen stem guide (18) from nozzle body (47).
(c) Remove piston torque tool and stem guide (18) from nozzle body (47).
5-8
|