TM 54930-235-13&P
(8) Attach ring (17) to dust plug (18).
(9) Insert end of wire rope (16) through ring (17).
(10) If wire rope (16) was damaged, assemble new sleeves (15) and wire rope (16) as follows:
(a) Form a loop with wire rope (16) and slide sleeves (15) on wire rope (16).
(b) Crimp one sleeve (15) to loop in wire rope (16).
(c) Repeat steps (a) and (b) on other end of wire rope (16).
(11) Insert dust plug (18) in coupling half (20).
(12) Push cam arms inward toward coupling half (20).
(13) Attach wire rope (16) to ring (13).
e 1 Reassembly (Unisex-model 125-0505).
NOTE
The strainer housing (24) need not be removed from the nozzle (1) except in those cases where
corrosion, cracks, or evidence of leakage is found. If the strainer housing is removed, the
threads must be cleaned with a brass-bristled wire brush to remove thread sealing compound.
(1) Apply a light, even amount of thread sealing compound to threads of the strainer housing (24).
CAUTION
Do not over-tighten. Failure to comply can result in damage to parts.
(2) If strainer housing (24) has been removed, thread strainer housing (24) into nozzle (1) until one to three
threads are exposed. Wipe off excess thread sealing compound.
CAUTION
Strainer must be installed carefully to prevent damage to O-ring.
(3) Place O-ring (23) and strainer (22) inside strainer housing (24).
(4) Apply a light, even coat of thread sealing compound to threads of unisex coupling half (20).
Change 1
4-8.1
|