TM5-4930-235-13&P
3. INADEQUATE FUEL FLOW.
Step 1. Remove coupling half, strainer body, and strainer from nozzle. Check strainer for dirt or other foreign
matter.
Clean strainer by removing all dirt and foreign matter.
Step 2. While strainer is removed, inspect for any damage.
Replace strainer if damaged. Install strainer in nozzle, then install strainer body and coupling half. Hand-
tighten only.
Section III. MAINTENANCE PROCEDURES
3-3. General. This section contains maintenance procedures which are the responsibility of the operator.
3-4. Coupling Gasket (Cam-Lock and Unisex model 125-0505). (See Figure 3-1).
INITIAL
SETUP
This task covers: Remove, Inspection, Installation, (Replacement and Reassembly-Univox model 125-0505 only).
Tools
None Required.
Materials/Parts
Lint-Free Cloth, MIL-C-85043 (Item 1, Appendix F)
a.
Removal (Cm-Lock).
(1)
Shut off fuel at source. Put handle in no flow (off) position.
NOTE
A suitable container should be available to catch fuel spillage.
(2)
Pull cam arms (1) outward from coupling half (2). Remove nozzle (3) from fuel hose.
(3)
Remove gasket (4) from coupling half (2).
a.1
Removal. (Unisex-model- 125-0505).
(1)
Shut off fuel at source and place handle (13) in no flow position.
NOTE
A suitable container should be available to catch any fuel spillage.
Change 1
3-2
|