TM 5-4930-234-13&P
NOTE
Before using this table, be sure all applicable operating checks have been performed.
Table 4-1. Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
DUST CAP ASSEMBLY DAMAGED.
Step 1. Inspect dust cap for corrosion, cracks, or distortion.
If damaged, remove from cable and install new dust cap.
Step 2. Inspect cable for corrosion, cuts, fraying and crimp of sleeves to cable.
If damaged, remove from dust cap and nozzle. Install new cable and sleeves.
2.
DUST PLUG ASSEMBLY DAMAGED.
Step 1. Inspect dust plug for corrosion, cracks, or distortion.
If damaged, remove from cable. Install new dust plug.
Step 2. Inspect cable for corrosion, cuts, fraying, and crimp of sleeves to cable.
If damaged, remove from dust plug and nozzle. Install new cable and sleeves.
3.
GROUND PLUG ASSEMBLY DAMAGED.
Step 1. Inspect ground plug for corrosion, cracks, or distortion.
If damaged, remove from cable. Install new ground plug.
Step 2. Inspect cable and cable eye for corrosion, cuts, fraying and crimp of sleeves to cable.
If damaged, remove from ground plug. Install new cable, cable eye, and sleeves.
4.
GROUND CLIP ASSEMBLY DAMAGED.
Step 1. Inspect ground clip for corrosion, cracks, or distortion.
If damaged, remove from cable. Install new ground clip.
4-2
|