TM 5-4930-234-13&P
2.
As required, uncoil cable on ground plug (7). Connect ground plug (7) to aircraft.
WARNING
Aviation fuel is highly flammable. No smoking or open flames are permitted during fueling
operations. Failure to comply can result in injury or death to personnel.
3.
Wipe area around fuel receptacle with a clean lint-free cloth to remove dust or foreign material.
4.
Remove fuel cap from aircraft fuel receptacle.
5.
Pull pullback sleeve (9) towards handle (11) and remove dust cap (8).
6.
Attach nozzle (13) to aircraft fuel receptacle.
7.
Press thumb latch (10). Move handle (11) up to FLOW (on) position.
8.
Operate fuel pump to dispense fuel to aircraft.
9.
Watch indicator pin (12). When it extends from the nozzle (13), shut off fuel pum p.
NOTE
For multi-refueling operations, fuel pump does not have to be shut off.
10.
Press thumb latch (10). Move handle (11) down to NO FLOW (off) position. Release handle (11).
11.
Pull pullback sleeve (9) toward handle (11). Remove nozzle (13) from fuel receptacle.
NOTE
A firm pull is required to remove nozzle assembly away from fuel receptacle.
12.
Wipe inside of dust cap (8), nozzle (13), and fuel receptacle with a clean, lint-free cloth to remove dust, dirt or
fuel.
13.
Install fuel cap on aircraft fuel receptacle.
14.
Install dust cap (8) on end of nozzle (13) by pulling pullback sleeve (9) toward handle.
15.
Disconnect ground plug (7) from aircraft. As required, coil ground plug cable.
16.
Disconnect ground clip (6) from grounding rod. As required, coil ground clip cable.
2-8
|