TM 5-4320-308-13 2-2.  OPERATING PROCEDURE (Continued) (1) Remove pipe plug (1) from priming port (2). (2) Pour fuel into priming port (2) to fill volute (3). CAUTION If volute does not fill with liquid, check suction hose assembly and suction hose connection at suction (intake) coupling for leaks.  Be sure that suction hose end or drum unloader is completely immersed in fuel. NOTE As  fuel  fills  volute,  air  is  removed  through  discharge  coupling.  As  the  air  is removed, fuel from the suction side of the pump is drawn into the volute and the pump will then draw on its own. (3) Install pipe plug (1) in priming port (2) and tighten securely. 2-7