TM 5-4320-306-24
2-18. REPLACE/REPAIR SUCTION ASSEMBLY, STRAINER ASSEMBLY, AND GATE VALVE (Continued)
ASSEMBLY:
1
Install preformed packing (10) and strainer (9) in
strainer body (5)
2
Install strainer clamp (8) on strainer body (5)
with locking lever (6) and lever bolt (7).
3
Tighten lever bolt (7) and lock locking lever (6).
4
Install 90-degree elbow (4) and reducer (3) on
strainer body (5).
5
Install suction pressure hose (2). Tighten hose
clamp (1) securely.
6
Install new gasket (15) and spool flange (14) on strainer body (16) studs with nuts (12) and lockwashers (13).
Tighten nuts.
7
Install new gasket (11) and gate valve (10) on spool flange (14) with cap screws (7), lockwashers (9), and nuts
(8). Tighten cap screws.
8
Install new gasket (6) and flange (5) on gate valve (10) with cap screws (1), lockwashers (2), and hex nuts (3).
Tighten cap screws (1).
2-70
|