TM 5-4320-306-24
2-18. REPLACE/REPAIR SUCTION ASSEMBLY, STRAINER ASSEMBLY, AND GATE VALVE (Continued)
7
Loosen hose clamp (1) and remove suction
pressure hose (2) from reducer (3)
8
Remove elbow (4) and reducer (3) from strainer
body (5).
9
Unlock locking lever (6) and remove lever bolt
(7)
10
Remove strainer clamp (8) from strainer body
(5).
11
Remove strainer (9) and preformed packing
(10). Discard preformed packing.
CLEANING/INSPECTION/REPAIR:
1
Inspect flanges, gate valve, strainer body, and strainer clamp for cracks, rust, corrosion, and for damaged or
stripped threads. Inspect mounting surfaces. Make sure they are smooth and flat with no nicks or burrs.
2
Repair minor nicks or burrs and/or smooth out mounting surfaces with crocus abrasive cloth. Clean interior or
mounting surfaces. Clean and refinish outside surfaces Remove only a minimal amount of surface material,
replace parts if necessary.
3
Inspect suction pressure hose (2). Replace if brittle, cracked, or deteriorated. Inspect hose clamp (1), reducer
(3), and 90-degree elbow (4) for damage, rust, or corrosion. Replace parts if severely damaged or rusted.
WARNING
Dry cleaning solvent P-D-680 (safety or Stoddard's Solvent) is potentially
dangerous. Avoid repeated and prolonged breathing of vapors and skin contact
with the liquid. Do not use near open flame, arcing equipment, or other ignition
source. Always wear eye protection and protective clothing. The flash point of P-
D-680 is 100° to 138°F (38° to 59°C).
Death or serious injury could occur if compressed air is directed against the skin.
Do not use compressed air for cleaning or drying unless the pressure is/has been
reduced to 30 psi (2.11 kgcm2) or less. When working with compressed air always
use chip guards, eye protection, and other personal protective equipment.
4
Clean strainer with dry cleaning solvent. Dry with compressed air.
5
Inspect strainer for damage. Replace if severely damaged.
2-69
|