2-6. SETUP INSTRUCTIONS
The centrifugal pump unit is shipped completely assembled except for the exhaust muffler and spark arrestor. Refer to
Operator's Manual, TM 5-4320-306-10, for setup and operating instructions.
2-7. INSPECTING AND SERVICING EQUIPMENT
a.
Inspect centrigural pump unit for any damage that may have occurred during shipping.
b.
Inspect unit for loose mounting hardware.
c.
Inspect unit for missing components.
d.
Refer to paragraph 2-1 for lubrication instructions.
e.
Refer to table 2-1 and perform preventive maintenance checks and services.
2-8. INSPECTING AND SERVICING BATTERIES
a.
The centrifugal pump unit battery box (1 ) contains two waterproof, lead acid storage batteries (2).
CAUTION
Disconnect battery cable from negative battery post before disconnecting any other leads
from engine components. This precaution will prevent short circuits which could
damage the alternator, voltage regulator, or other electrical components.
When removing battery cable, use battery terminal puller to remove loosened terminal
lugs. Forcing battery terminal lugs off without using puller may damage the battery
posts.
Never disconnect battery while alternator is operating.
Never attempt to polarize the alternator.
b.
Open battery box top (3). Remove battery cables and batteries (2) from battery box (1) and inspect
for damage.
c.
Clean positive terminals (4) and negative terminals (5)
2-6
|