ASSEMBLY/TEST:
1
Assemble screws (28), nuts (2, 6, and 10), and
terminal lugs (3, 7, and 11) onto positive battery
cables (8), negative battery cables (4), and jumper
battery cable (12).
2
Test positive battery cable assembly and negative
battery cable assembly for electrical continuity
between terminal lugs (3 and 7) and opposite end of
cables.
3
Test jumper battery cable assembly for electrical
continuity between the two terminal lugs (11).
4
Inspect cables that do not have continuity for good
electrical connection between cable ends and
terminal lugs. If connections are good, inspect cable
according to INSPECTION/ TEST/REPAIR steps 6,
7, and 8.
INSTALLATION:
1 Reconnect positive battery cable (8) to starter relay
(27).
2-40
|