TM 5-4320-305-24 2-23.  REPLACE ETHER START KIT This task covers: a.  Test c.  Inspection b.  Removal d.  Installation INITIAL SETUP Tools Equipment Condition Shop equipment, automotive maintenance Para Condition Description and repair, common no.  1 2-16 Control panel cover assembly re- Tool kit, general mechanics automotive moved. WARNING Ether is highly flammable.  Do not use near sparks or open flame. Do  not  inhale  fumes.    Do  not  operate  valve  for  more  than  three seconds.    Overloading  the  engine  air  housing  with  this  highly flammable fluid (ether) could result in an explosion. TEST: Pull knob (1) for 3 seconds or less to test operation.  If valve (2) operates but no ether is released, then replace cylinder (3) and test valve (2) again.  If still no ether is released, replace valve (2). 2-92