TM 5-4320-304-14
TM 08922A-14/1
Equipment operation is allowable with minor leakages (Class
I or II). Of course, you must consider the fluid capacity in
the item/system being checked/inspected. When in doubt,
notify your supervisor.
When operating with Class I or Class II leaks, continue to
check fluid levels as required in your PMCS.
Class III leaks should be reported to your supervisor or
organizational maintenance.
Table 2-2. Operators Preventive Maintenance Checks and Services
NOTE
If the equipment must be kept in continuous operation,
check and service only those items that can be checked and
serviced without disturbing operation. Make the complete
checks and services when the equipment can be shut down.
Perform weekly as well as before operation PMCS if:
Item
No.
1
(1) You are the assigned operator and have not operated
the item since the last weekly.
(2) YOu are operating the item for the first time.
Within designated interval, these checks are to be performed
in the order listed.
B - Before Operation
A After Operation
M Monthly
D During Operation
W Weekly
B
Interval
D
A
W
M
l
ITEM TO BE INSPECTED
Equipment is
Not Ready/
PROCEDURE
Available If:
Frame Assembly and Warning Plates.
Check attaching hardware used to mount components
of centrifugal pump unit. Attaching hardware shall
be tight and free of corrosion and damage. Compo-
nents of pump attached directly to frame (1) are:
Warning plates (2)
Engine brackets (3)
Identification plate (4)
Cracks are de-
tected, or engine
is loose.
2-5
|