TM 5-4320-273-14
Table 31. Operator/Crew Preventive Maintenance Checks and Services (cont)
A After
D During
Q-Quarterly
B Before
.
-
Procedures
Item
Equipment is Not Ready/
Interval
Item to be
Check for and have repaired
Available If
No. B D A Q
Inspected
or adjusted as necessary
Pressure drops below 1
f. Oil pressure Indicates 4 to 5 lbs/sq in. at idle.
lb/sq in.
Gage
WARNING
Do not fill tank while engine is running.
q
Fuel System
Fill fuel tank.
3
WARNING
Do not smoke or use an open flame in
the vicinity when servicing the battery.
Batteries generate hydrogen gas, which
is highly explosive.
NOTE
Use distilled water or a good grade
drinking water (excluding mineral water).
4
q Battery
Check level of electrolyte. If low, fill
with clean water (distilled if possible) to
the split ring. In freezing weather,
charge battery at least 1 hour after
adding water.
Section III. TROUBLESHOOTING
3-8. General.
Perform the tests/inspections and corrective actions in
a. This section contains troubleshooting
the order listed.
information for locating and correcting most of the
operating troubles which may develop in the pumping
Each malfunction for an individual
assembly.
component, unit, of a system is followed by a list of
b. This manual cannot list all malfunctions that
tests or inspections which will help you to determine
may occur, nor all tests or inspections and corrective
probable causes and corrective actions to take.
3-4.2 Change 4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |