and discharge hoses are disconnected before you
manifold are damaged, you must replace the entire
begin to disassemble the piping.
manifold.
(2) Disconnect the pump pressure gage hose
(4) Replace all damaged or defective parts.
from the air eliminator housing.
(5) Touch up or repaint all areas requiring it.
(3) If the gages and instruments are con-
c. Reassembly and Installation. Using all new
nected to the control panel, make sure you properly
gaskets, reassemble the suction piping in the
support the panel when removing it from the piping
reverse order of disassembly; refer to figure 4-16.
to avoid damaging the instrument leads and cables.
After reassembly, start and operate the centrifugal
( 4 ) Disassemble the discharge piping as
pump and check for leaks. Correct any deficiencies.