TM  5-4320-228-13&P 2-5. STARTING THE EQUIPMENT. Before you operate. Always keep in mind the CAUTIONS and WARNINGS. a. Preparation for Starting. (1)  Do  the  before  operation  preventive  maintenance  services (para  2-2). (2) Prime pump as described in figure 2-2, if pump is not full of water. Do not start pump without first priming with  water. Dry operation will damage pump  seals  and  cause  pump  to  fail.  After priming, do not run pump more than 3 to 5 minutes without water flowing through it. Figure 2-2. Priming  pump. b. Starting. Start pump as shown below: NOTE Allow engine sufficient warm up time before starting pumping operations. (See caution in  para  2-5a(2).) 2-8