TM 5-3825-220-13&P 6-4.3  50,000 Gal.  Fabric Collapsible Tanks and Appurtenances a. Refer to the technical manuals noted in para.  6-1.4. b. It  is  recommended  that  the  tank(s)  be  removed  from  service,  action  be  taken  to  determine  the  cause,  and corrective  maintenance  action  be  taken  in  accordance  with  the  technical  manual  referenced  above  whenever  the following occur: 1.  Fuel inside the berm. 2.  Tank top not laying essentially flat at the fuel level. 3.  Serious scratch or scoring on the tank surface 4.  Pump cannot take suction off the tank 5.  Fuel not entering the tank as intended 6.  Leaking tank valves 7.  Leaking hoselines to or from the tank 6-4.4  Filter-Separator (GFE) a. Refer to the technical manual noted in para.  6-1.5. b. It is recommended that a filter-separator be removed from service, action be taken to determine the cause, and corrective  maintenance  action  be  taken  in  accordance  with  the  technical  manual  referenced  above  whenever  the following occur: 1.  Excessive or premature pressure drop 2.  Leaking head flange joint 3.  Leakage of any kind 4.  Excessive or premature water carryover as evidenced by sample from the water detector kit adaptor 5.  Rattling nozzle when flowing 6-4.5  Flood Light Set (GFE) a. Refer to the technical manuals noted in para.  6-1.6. b. It  is  recommended  that  the  tank(s)  be  removed  from  service,  action  be  taken  to  determine  the  cause,  and corrective  maintenance  action  be  taken  in  accordance  with  the  technical  manual  referenced  above  whenever  the following occur: 1.  No power generated to lighting unit 2.  Lighting tower swaying or offset 3.  Excessive engine noise or vibration 4.  Electrical shock when touching 5.  Electrical arcing anywhere 6.  Fuel leakage 6-4.6  Wheel-Mounted Dry Chemical/AFFF Fire Extinguishers a. Detailed instructions on the maintenance of the wheel-mounted dry chemical/AFFF fire extinguishers are in the Marine Corps technical manual TM 076618-14/1 contained in this manual under Appendix A. 6-15

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business