Setup Distillation Unit.
Assemble Heater. Refer to figure 2-9.
NOTE
Distillation unit refractory is recessed into heater housing. If refractory
is not recessed, flash point tester and distillation unit heaters may have
been switched.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Refer to loading plan (figure 2-6) and remove distillation unit components from cabinet.
Separate all components to aid assembly.
Install two dovetail clamps (1 and 2) on back of heater (3).
Screw rod (4) into stand (5).
Position heater (3) on rod (4). Tighten upper dovetail clamp (l), then lower dovetail clamp
(2) to secure heater on rod.
Place clay refractor (6) on top of heater (3) with concave surface facing up.
Install flask clamp (7) on rod (4).
Install flask holder (8) on flask clamp (7).
NOTE
Adjust flask holder and clamp as required to center flask on clay
refractor.
(9)
Place neck of flask (9) in flask holder (8). Position flask in holder so that bottom of flask is
about 1/8-inch from concave surface of clay refractor (6), then tighten flask holder.