| |
TM 10-5430-242-12&P
0012 00
0012 00-1/2 blank
Change 1 28 April 2002
OPERATOR AND UNIT MAINTENANCE MANUAL
(INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)
COLLAPSIBLE FABRIC TANKS, FUEL STORAGE, 3,000,
10,000, 20,000, AND 50,000 GALLON
FILLER/DISCHARGE BALL VALVE GASKET (RELIANCE AND MPC MODELS)
REPLACEMENT
INITIAL SETUP
Mandatory Replacement Parts
Gasket
(Item 2, WP 0044 00)
REMOVAL
1. Pull cam-lever arms (1) on dust cap (2) out, away from body of dust cap (2).
2. Remove dust cap (2) from male coupling (3). Remove gasket (4) from dust cap (2).
3. Pull cam-lever arms (5) on female coupling (6) out, away from body of female coupling (6).
4. Remove dust plug (7) from female coupling (6). Remove gasket (8) from dust plug (7).
5. Discard gaskets (4, 8).
INSTALLATION
1. Install new gasket (8) on dust plug (7).
2. Push cam-lever arms (5) on female coupling (6) outward, away from body of female coupling (6).
3. Install dust plug (7) in female coupling (6).
4. Push cam-lever arms (5) on female coupling (6) inward toward body of female coupling (6) until
locked.
5. Install new gasket (4) on dust cap (2).
6. Push cam-lever arms (1) on dust cap (2) outward, away from body of dust cap (2).
7. Install dust cap (2) on male coupling (3).
8. Push cam-lever arms (1) on dust cap (2) inward toward body of dust cap (2) until locked.
END OF WORK PACKAGE
1
2
3
4
5
6
7
8
|