TM 10-5430-239-12&P
0027 00
SERVICE
WARNING
Dry cleaning solvent A-A-59601, used to clean parts, is potentially dangerous
to personnel and property. It produces toxic and flammable fumes. Use only
in well-ventilated areas. Avoid repeated and prolonged skin contact.
Do not use near an open flame or excessive heat. The flash point of solvent is
100F to 138F (38C to 59C).
1. Clean all parts with dry cleaning solvent and dry thoroughly with rags.
2. Clean all gasket surfaces thoroughly with cleaning compound and hot water.
3. Inspect all mechanical parts for cracks, dents, breaks or wear. Replace or repair if unserviceable.
4. Polish bonnet stem with an abrasive (crocus) cloth then coat with grease.
0027 00-4
|