TM 10-5430-239-12&P
0022 00
ASSEMBLY
1. Lubricate new o-ring (11) with silicone compound. Position o-ring (11) into the packing groove
located on the tank fitting.
2. Position drain cover plate (3) on the tank fitting, and align the fastening holes.
3. Install drain cover plate (3) and bracket (8) to the tank fitting with eight screws (9) and washers (10),
by hand tightening screws (9).
4. Attach the S-hook of chain assembly (4) to bracket (8). Torque all screws (9) to 10 ft-lbs (13.5 Nm).
5. Apply sealing compound or anti-seize tape to drain plug screw (6) threads.
6. Install drain plug screw (6), bracket (5), and drain plug (7) to drain cover plate (3). Attach the S-hook
of chain assembly (4) to bracket (5).
7. Apply sealing compound or anti-seize tape to threads of drain hose (2).
8. Engage threads of drain hose (2). Turn drain hose (2) clockwise until tight.
9. Engage threads of ball valve (1) and drain hose (2). Turn ball valve (1) clockwise until tight.
END OF WORK PACKAGE
0022 00-3/4 blank
|