6. Remove o-ring (11) from the packing groove located in the tank fitting. Discard o-ring (11).
SERVICE
WARNING
Dry cleaning solvent, A-A-59601, used to clean parts, is potentially
dangerous to personnel and property. It produces toxic and flammable
fumes. Use only in well ventilated areas. Avoid repeated and prolonged
skin contact. Do not use solvent near an open flame or near excessive
heat. The flash point of the solvent is 100F to 130F (38C to 59C).
CAUTION
Dry cleaning solvent, A-A-59601, used to clean parts, must not come into
contact with any part of the fuel tank fabric. Damage to the fabric will
occur.
1. Clean all parts with dry cleaning solvent and dry thoroughly with rags.
2. Clean packing grooves thoroughly with detergent and hot water.
3. Inspect all mechanical parts for cracks, dents, breaks, and wear. Replace the component if
unserviceable.
1
2
7
11
3
6
5
10
8
4
9
0022 00-2