Attach Vent Assembly
1. Remove dust cap (1) from male coupling half (2).
2. Inspect female coupling half (3) and vent standpipe (4) for cleanliness. If dirty, wipe off with a clean
rag.
NOTE
Normally coupling half and vent standpipe will be received pre-assembled.
3. Make sure relief cap (5) operates freely and flame arrester (6) is installed.
4. Check to see that relief cap (5) is lightly installed on vent standpipe (4).
5. Check to see that gasket (7) is in place in female coupling half (3) and correctly sealed.
6. Insert female coupling half (3) on male coupling half (2) with cam-lever arms (8) in outward position.
At the same time, press cam-lever arms (8) upward and inward to lock vent standpipe (4) in operating
position.
5
3
6
8
7
2
4
1