TM 10-5430-238-12&P
0026 00
SERVICE
WARNING
Dry cleaning solvent, A-A-59601, used to clean parts, is potentially dangerous to
personnel and property. It produces toxic and flammable fumes. Use only in well
ventilated areas. Avoid repeated and prolonged skin contact. Do not use solvent
near an open flame or near excessive heat. The flash point of the solvent is 100F
to 130F (38 C to 59 C).
1. Clean all parts with dry cleaning solvent, and dry thoroughly with rags.
2. Clean the preformed packing grooves with cleaning solvent, and dry thoroughly with rags.
3. Inspect all mechanical parts for cracks, dents, breaks, and wear. Replace the component if
unserviceable.
4. Check that the vent hole in the flame arrestor is clear of all debris.
ASSEMBLY
1. Install screw (17), washer (18), and new gasket (19) in lever head assembly (20).
2. Position new relief cap gasket (13) over flame arrestor (14). Seat relief cap gasket (13) into
relief cap (12).
3. Install flame arrestor (14) into relief cap (12). Rotate flame arrestor (14) clockwise until threads
are firmly seated in relief cap (12).
4. Install flame arrestor (14) into vent pipe (11) until vent pipe (11) contacts relief cap (12).
5. Rotate relief cap (12) clockwise until vent pipe (11) and relief cap (12) are firmly seated together.
6. Install vent pipe (11) into female quick-disconnect coupling (8). Rotate vent pipe (11) clockwise until
it firmly seats in female quick-disconnect coupling (8).
7. Install new gasket (10) into female quick-disconnect coupling (8).
8. Install female quick-disconnect coupling (8) on male-flanged adapter (4) pushing in cam-lever arms (9)
until locked in place.
9. Install new gasket (15) inside dust cap (16).
INSTALLATION
1. Lubricate new O-ring (6) with silicone compound.
2. Install O-ring (6) into packing groove (7) located in tank fitting (5).
3. Position male-flanged adapter (4) over tank fitting (5).
4. Install eight washers (2) and screws (1) through vent and pipe assembly (3) and tank fitting (5) holes.
5. Torque screws (1) to 30 in-lb (3.41 Nm).
END OF WORK PACKAGE
0026 00-3/4 blank