TM 10-5430-238-12&P
0017 00
ITEM TO BE
EQUIPMENT
MAN-
CHECKED OR
PROCEDURE
NOT READY/
ITEM
INTERVAL
HOUR
SERVICED
AVAILABLE IF:
NO.
Check for bent or binding stem,
Stem, hand-
11
During
Filler/Discharge
broken hand-wheel, and
wheel, gasket, or
Gate Valve (2)
leakage.
cam-lever arms
(Models
are damaged,
WTM3KF, MIL-
missing, or
T-52983B,
leaks.
M52983-50,
PD52983-50,
BA92-162,
FCE574-81-1-A,
SC5430-
97CLE01)
12
During
Filler/Discharge
Check for bent or binding stem,
Stem, handle,
Butterfly Valve
broken handle, and leakage.
gasket, cam-
Assembly (3)
lever arms are
(Models BA91-
damaged or
141 &
leaks.
BA91-140)
13
During
Filler/Discharge
Check for bent or binding stem,
Stem or handle
Ball Valve (4)
broken handle, and leakage.
is damaged or
(Models BA91-
leaks.
141A &
BA91-140A)
14
During
Drain Gate
Check for bent or binding stem,
Stem or hand-
Valve (5)
broken hand-wheel, and
wheel is
(Models
leakage.
damaged,
WTM3KF,
missing, or
M52983-50,
leaks.
BA92-162,
FCE574-81-1-A,
SC5430-
97CLE01)
15
During
Drain Ball Valve
Check for bent or binding stem,
Stem or handle
(6)
broken handle, and leakage.
damaged,
(Models BA91-
missing, or
141 & BA91-
leaks.
140, PD52983-
50, BA91-141A
& BA91-140A)
16
During
Vent and Pipe
Check for evidence of leakage,
Relief cap or
Assembly (7)
damage, or missing parts. Check
flame arrestor is
the relief cap for cleanliness and
damaged or
freedom of operation. Check if
missing. Relief
the flame arrestor, relief cap
cap gasket, flat
gasket, flat rubber gasket, or
rubber gasket, or
cam-lever arms are damaged or
cam-lever arms
missing.
are damaged or
missing.
0017 00-6
|