Click here to make tpub.com your Home Page

Page Title: Filler/discharge assembly elbows leak.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-5430-238-12&P
0008 00
Check the preformed packing between the closure plate and the tank fitting for
nicks, breaks, and compression.
CORRECTIVE ACTION
Replace the preformed packing. See WP 0027 00.
SYMPTOM
Filler/discharge assembly leaks between the closure plate and flanged adapter.
MALFUNCTION
Check for missing or loose nuts, lockwashers, thread seal washers, and hex
head cap screws.
CORRECTIVE ACTION
Replace missing nuts, lockwashers, thread seal washers, and
hex-head cap screws Torque the fastening hardware to 30 in-lb
(3.41 Nm). See WP 0027 00.
Check the flange gasket for damage or wear.
CORRECTIVE ACTION
Remove the flange adapter from the closure plate and replace
the damaged flange gasket. See WP 0027 00.
SYMPTOM
Filler/discharge assembly leaks through hardware or will not assemble.
MALFUNCTION
Check all filler/discharge fastening hardware for cracks, damages, and wear.
CORRECTIVE ACTION
Replace the fastening hardware as required. Torque the
fastening hardware to 30 in-lb (3.41 Nm). See WP 0027 00.
SYMPTOM
Filler/discharge assembly elbows leak.
MALFUNCTION
Check elbows for cracks, dents, or wear. Check for damaged or missing elbow
gaskets.
CORRECTIVE ACTION
Replace damaged elbows and gaskets. See WP 0027 00.
0008 00-7

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business