TM 10-4930-250-13&P 4.   Pumpoperatesatlow capacity. Step  1.   Check  for   blockage. a. Disconnect   lines  from   inlet  and  outlet  unisex  couplings. b. Open coupling   valves  and visually    inspect  for  blockage.   Remove  any  blockage. Step 2. Check  for  clogged   strainer. a. Separate  pump  from   inlet   reducer. b. Remove   and clean  strainer. Step  3.    Replace  pump. ENGINE Refer  to  TM   10-4320-351-14. FUEL   TRANSFER   PUMP Refer  to  TM   10-4320-351-14. FILTER-SEPARATOR, WATER,   LIQUID    FUEL Refer  to  TM   10-4330-237-13&P. D-1  NOZZLE Refer  to  TM   104930-246-13&P. CCR  NOZZLE    ASSEMBLY Refer  to  TM   10-4930-248-13&P. 4-7