Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: CCR NOZZLE ASSEMBLY REPAIR - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM    10-4930-248-13&P 5-2. CCR NOZZLE ASSEMBLY REPAIR - continued. d. Testing    - continued. WARNING Drycleaning solvent,   P-D-680    Type   III,  used   to  clean   parts   is  potentially dangerous to  personnel and  property. Use  in  a  well-ventilated area   as the fumes   are  dangerous if inhaled. Avoid   repeated and  prolonged skin   contact. Do  not  use  near   open   flame   or  excessive heat.    Flash   point   of solvent    is  138'F. NOTE There   shall    be no  evidence    of leakage during    flow  conditions, binding, valve chatter, distortion, or  requiring excessive    force   at  connecting and disconnecting of the  nozzle   to  the   test   adapter. (2) Pressure test   with   nozzle    in  the   OPEN   (flow)   position. (a) Position nozzle   handle (1)  in  the   CLOSED (no  flow)  position and   connect nozzle assembly (9) to  test   adapter outlet    (2) and  test   adapter inlet   (3). (b) Close   valve   (8) and  move   nozzle   handle (1) to  the  OPEN    (flow)  position. (c) Adjust    pump   (5) to  5 psig   at  the   nozzle   inlet   gage   (4) and   maintain pressure for  1 minute minimum. (d) Slowly    increase pump   (5) pressure to  90  psig   at  gage   (4) and   maintain pressure for  1 minute minimum. (e) Reduce   pump   (5)  pressure to  20  psig   and   open  valve   (8). (f) With   nozzle   handle (1) in  the  OPEN   (flow)  position, remove    nozzle   from   adapter (2). There    shall    be  no  evidence of leakage from   the   nozzle    discharge end. (g) Move  nozzle   handle (1) to  the   CLOSED (no  flow)  position and   reduce    pump    (5) pressure to  zero. (3) Pressure test   with   nozzle   in  the   CLOSED (no  flow)  position. (a) Move  nozzle   handle (1)  to  the  CLOSED    (no  flow)  position. (b) Disconnect Nozzle   (1) from   test   adapter outlet   (2). (c) Adjust    pump   (5) to  5  psig   at  the   nozzle   inlet   gage   (4) and   maintain pressure for  1 minute minimum. (d) Slowly    increase    pump    (5) pressure to  90  psig   at  gage   (4)  and   maintain pressure for  1 minute minimum. (e) Reduce pump   (5)  pressure to  zero. 5-20

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business