TM 10-4930-248-13&P
4.10B.
REPAIR UNISEX COUPLING.
This task consists of-
a. Disassembly
b. Inspection
c. Assembly
INITIAL SET-UP:
Tools:
Materials/Parts
Required:
Tool Kit, General Mechanics
None
(Item 1, Appendix B)
General
Safety Requirements:
Equipment
Condition:
Unisex coupling removed from CCR nozzle
WARNING
(para. 4.10A.)
Fuels are toxic and flammable. Do not get on person
or clothing. Do not use near open flame. Area
should be well ventilated.
Using dry cleaning solvents incorrectly can cause
injury or even death.
Fuel is flammable.
Do not smoke.
NOTE
Inspect the coupling components as they are disassembled.
Repair is limited to
replacement
of unserviceable
components
discovered during disassembly.
a. Disassembly and Insvection.
(1)
Remove spring (1) from unisex coupling (2).
(2)
If the dust cap (3) or cable (4) is to be replaced, cut cable (4) to remove.
(3)
The ring (5) attaching cable (4) to unisex coupling (2) may be removed from the cable (4) by rotating it through
the split portion of the ring (5).
(4)
Remove the bumper (6) only if it is to be replaced or the lugs (7 and/or 8) must be replaced.
(5)
Remove screws (9) to remove lugs (7 and/or 8).
(6)
Remove locking pin (10) and spring (11).
4-12.2