TM 10-4930-247-13&P Table 4-1.  Unit Preventive Maintenance Checks and Services for Model HTARS100. Item Location No. Interval Item Procedure Check/Service 1 Monthly All Fuel Hoses Using a multimeter, test fuel hose for broken, or disconnected internal ground cable as follows: (1)  Place multimeter leads against metal surfaces of both couplings. (2)  Check for continuity between couplings.  Continuity must exist.  If continuity does not exist, hose is defective. 4-5/(4-6 Blank)