TM 10-4930-246-13&P
5-4.
BODY ASSEMBLY REPAIR. - continued
3
5
Figure
5.2.
Adapter
(4)
Remove fuel nozzle body assembly (6) from nozzle collar (3) by aligning the groove in the collar with dent
on body and pulling body from collar.
(5)
Remove adapter (5).
(6) Turn Lever (7) to open poppet
(7) Remove cotter pin (9) and unscrew the poppet (8) from the shaft (10).
(8) Remove the nozzle seal assembly (11), (12), and (13) by lifting off body (6).
(9) Remove bearing reWning plate (12) from the seal (11) by spreading the ends of the retaining ring (13) and
removing it from the groove in the seal. Slide plate off seal.
(10) Remove three lock pins (14), three lock pin springs (15), three index pins (16) and O-ring (17).
(11) Remove two plugs (18).
NOTE
Observe the orientation of the cam plate with respect to lever so that it can be duplicated
during reassembly. Mis-orientation will result in not being able to close nozzle properly.
(12) Remove screws (19) through plug (18) opening.
,en