TM 10-4930-246-13&P
Table 2-1.1 Operator Preventive Maintenance Checks and Services for D-1R Nozzle
Location
Item
Interval
Item to Check/Service
Procedure
Not Fully Mission Capable If:
No.
5 NOZZLE BODY ASSEMBLY
COLLAR LOCK PINS
LEVER
co"
INDEX PINS
6
During
Nozzle Assembly
Check for leaks.
Any leak is found.
6 NOZZLE
ASSEMBLY
7
After
Unisex Disconnect
Check body for any deformation,
Any damage would interfere with
Assembly
cracks, or internal gouges.
installation
or cause leaks.
After
Check that face seal is in place
Face seal is missing or damaged.
and not damaged.
After
Depress continuity
ball on valve
Continuity
ball does not pop back
seat and observe that ball pops
out.
back out. If ball does not pop back
out, the unisex coupling must be
replaced. Notify
unit maintenance
After
Check strainer for obstructions
or
Strainer obstructed or torn.
tears.
2-12.2
Change
1
|