TM 10-4930-246-13&P
Location
Item
Interval
Item to Check/Service
Procedure
Not Fully Mission Capable If:
No.
3
Before
Inlet Elbow Assembly
Check elbow for cracks.
Damaged enough to cause leaking
or interfere with operation.
4
Before
Grounding Cable
Check that grounding cable,
Grounding cable, bonding plug,
Assembly
bonding plug, and grounding clip
and grounding clip are broken or
are in place and in good
missing.
condition.
5
Before
Handles
Check that handles are in place
Handles missing or damaged
and in good condition.
enough to prevent operation.
j
4 GROUNDING CABLE
3 INLET ELBOW ASSEMBLY,'
LY
5 HANDLES
6
Before
Nozzle Body Assembly
Inspect connection end and verify
Index pins or collar lock pins
that index pins are intact, in
missing, worn or damaged.
place, and not excessively wom
or damaged.
PROTECTIVE
LEVER
PLASTIC
0@
DUST COVER
COLLARR/
COLLAR LOCK PINS
7,(r
6 NOZZLE BODY
ASSEMBLY
INDEX PINS
2-7
|