TM 10-4930-246-13&P
Table 2-1. Operator PreventiveMaintenanceChecksand Servicesfor D-1 Nozzle
Location
Item
Interval
Item to Check/Service
Procedure
Not Fully Mission Capable Ifi.
No.
I
Before
Camlock Disconnect
Check camlock casting for any
Any damage that would interfere
Assembly
deformation, cracks, or internal
with installation or cause leaks.
gouges.
Before
Check camlock levers for smooth
Camlock levers binding, broken,
operation and damaged or missing
or missing.
lever arms or rings.
Before
Check that gasket is in place and
Gasket missing or damaged.
not damaged.
1
CAMLOCK DISCONNECT
ASSEMBLY
2
Before
Strainer and Quick
Check quick disconnect assembly
Damaged enough to cause leaking
Disconnect Male Adapter
for cracks.
or interfere with operation.
Assembly
Before
Check for missing or loose flange
Flange hardware or lock wire
hardware or lock wire.
missing or loose.
Before
Check strainer for obstructions or
Strainer obstructed or tom.
tear.
2
?
STRAINER AND
@E@
QUICK DISCONNECT MALE ADAPTER
ASSEMBLY
2-6
|