a.
Disassembly
b.
Repair
c.
Assembly
INITIAL SET-UP:
Tools:
Equipment Condition :
Tool kit, General Mechanics (Item 1, Appendix B)
CCR Nozzle removed from fuel system.
Vise (Item 2, Appendix B)
(Reference Applicable System TM)
General Safety Requirements:
Materials/Parts Required:
Solvent (Item 1, Appendix E)
WARNINGS
Wiping Rag (Item 2, Appendix E)
Fuels are toxic and flammable. Do not get on
Silicone Compound (Item 3, Appendix E)
person or clothing. Do not use near open flame.
Sealing Compound (Item 4, Appendix E)
Area should be well-ventilated.
Packing, Preformed (Item 1, Appendix H)
Using drycleaning solvents incorrectly can cause
injury or even death.
Fuels Flammable/No Smoking
a.
Disassembly
(1)
Pull the nozzle collar (1) back to release the cap (2) from the discharge end of the nozzle. Remove
the cap assembly (2).
(2)
Remove screw (3) holding the ground cable assembly (4) and cap assembly cable (2) to the nozzle
housing (5).
(3)
Remove strainer body (6) with coupling assembly (10) attached, by hand from strainer housing (7).
(4)
Remove strainer (8) and preformed packing (9) from strainer housing (7). Discard packing.
(5)
Place strainer body (6) into a soft face vise.
(6)
Unscrew coupling assembly (10) from strainer body (6).
(7)
Remove plug (11) from coupling half (13).
(8)
Remove gasket (12) from coupling half (13).