TM 10-4930-242-13&P
5-2.
D-1 FUELING NOZZLE REPAIR - continued.
b.
Repair.
WARNING
Drycleaning solvent, AA 711, Types I and II, used to clean parts, is
potentially dangerous to personnel and property Eye protection required.
Avoid repeated and prolonged skin contact by wearing rubber or
nonporous gloves when handling solvents or material wet with dry-
cleaning solvent. Wash hands immediately after exposure with soap
and water and use a lanolin based skin cream to prevent skin drying. Do
not use near open flame or excessive heat. Flash point of solvent is
138°F. Do not work with solvent in a closed room. Be sure there is
good ventilation or the solvent vapors will build up in the air and become
a poisonous mixture which can cause physical injury or even death.
(1)
Wash all parts with cleaning solvent, federal specification AA 711.
WARNING
Compressed air can blow dust into the eyes. Wear eye protection. Do
not exceed 30 psig working pressure.
(2)
Dry thoroughly with a clean cloth or compressed air.
(3)
Inspect parts visually for cracks, wear, cuts, tears or holes.
(4)
Inspect springs for distortion or broken coils.
(5)
Inspect for bent or broken pins or locks.
(6)
Inspect threaded surfaces for damaged or stripped threads.
(7)
Inspect mating parts for scoring, nicks or wear.
(8)
Replace defective components.
5-9
|