TM 10-4930-241-13
2-21. PREPARATION FOR MOVEMENT - CONT.
c.
600 GPM Pump Ground Rod Removal. Refer to figure 2-44.
WARNINGS
Do not touch surfaces with bare skin. Bare skin will freeze to
metal surfaces in subzero temperatures. Always wear arctic
mittens when handling components.
Exercise care to prevent injury when removing ground rod from the soil. Wear gloves to
protect your hands.
(1)
Loosen nut (9) and remove ground wire (7) from slot in ground lug (10) on pump (11).
(2)
Loosen screw (8) and disconnect ground wire (7) from front plate (5).
(3)
Loosen screws (4),rotate plate (5) from back plate (6) and remove clamp
(4)
Lift slide (2) forcefully against upper stop collar (3). Repeat until ground rod (1) is pulled from ground.
Figure 2-44. 600 GPM Pump Ground Rod Removal.