TM 10-4930-240-13
Table 2-1. Operator Preventive Maintenance Checks and Services for Model AFARE100 - cont.
Location
Item
Interval
Procedure
Not Fully Mission
No.
Item to
Capable If:
Check/Service
20
During
CCR Nozzle and
Perform "DURING" PMCS in accor-
Gravity Fill
dance with TM 10-4930-243-13&PE!
Adapter
21
During
Single Point
Perform "DURING" PMCS in accor-
Refueling Nozzle
dance with TM 104930-242-13&P
(D1)
22
During
Discharge Hoses
Inspect hose material and quick dis-
Any fuel leak
connect couplings for leaks
23
During
Wyes/Reducers
Inspect body and quick disconnect
Any fuel leak.
couplings for leaks.
24
During
Valve Section
Inspect valve and quick disconnect
Any fuel leak.
couplings for leaks.
25
During
Filter Separator
Perform "DURING" PMCS in accor-
dance with TM 10-4330-23613.
26
During
Air Duct
Check that air ducts are securely con-
Air duct not connected.
nected between deflector assembly
and filter separator.
27
During
Deflector
Check that deflector is securely
Deflector loose.
Assembly
mounted to 200 gpm pump.
28
During
200 Gpm Pump
Perform "DURING" PMCS in accor-
dance with TM 10-4320-342-10.
29
During
Suction Hoses
Inspect for leaking or collapsed hose.
Hose collapsed; any fuel
Inspect quick disconnect couplings
leak.
for leaks
30
During
Fueling
Inspect manifold piping, gate valves
Any fuel leak.
Manifold
and quick disconnect couplings for
Assembly
leaks.
31
During
Pressure
Inspect pressure reducer, piping, gate
Any fuel leak
Reducing
valve and quick disconnect couplings
Assembly
for leaks.
32
During
Tees
Inspect
tee
body
and
quick
disconnect
Any fuel leak
couplings for leaks.
33
During
Couplers
Inspect coupler body and quick dis-
Any fuel leak
connect coupling for leaks.
2-30
|