TM 10-4930-240-13 4-35.  ADAPTER ASSEMBLY REPAIR-cont. b.  Cleaning. WARNING Dry cleaning solvent, P-D-680, Type III, is potentially dangerous to personnel and equipment.    Eye  and  skin  protection  is  required.    Avoid  repeated  and  prolonged skin  contact.    Wash  hands  immediately  after  exposure.    Do  not  use  near  open flame or excessive heat.  Use only in areas with good ventilation. Using wiping rags and cleaning solvent, remove dirt and contaminants from all components. c.  Repair.  Replace damaged or defective parts and all sealing components. d.  Assembly. Refer to figure 4-23. (1)  Apply thread sealant to male threads of male coupling half (8). (2)  Connect male coupling half (11) on male coupling half (8). (3)  Install gasket (12) in dust cap (10). (4)  Install dust cap (10) on male coupling half (11). (5)  Install gasket (9) in dust cap (7). (6)  Install dust cap (7) on male coupling half (8). (7)  Install chains (5 and 6) and three split rings (2, 3, and 4). 4-70

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business