TM 10-4930-240-13
4-30. FUELING MANIFOLD ASSEMBLY REPAIR - cont.
c. Cleaning.
WARNING
Dry cleaning solvent, P-D-680, Type III, is potentially dangerous to personnel and
equipment. Eye and skin protection is required. Avoid repeated and prolonged
skin contact Wash hands immediately after exposure. Do not use near open flame
or excessive heat. Use only in areas with good ventilation.
Using wiping rags and cleaning solvent, remove dirt and contaminants from all components.
d. Repair. Replace damaged or defective parts and all sealing components.
e. Assembly. Refer to figure 4-19.
CAUTIONS
To prevent premature failure of fueling manifold assembly, gaskets certified for
arctic service must be installed. If a new dust cap or female coupling half has
been installed, remove and discard black gaskets supplied with the new
components and replace them with arctic service gaskets.
Ensure gasket is fully seated in gasket seat of coupling/dust cap to prevent leaks
in assembled components.
(1) Apply thread sealant to male threads of all threaded threaded components.
(2) Install female coupling half (31) on gate valve (32).
(3) Install gasket (30) in female coupling half (31).
(4) Install dust plug (29) in female coupling half (31).
(5) Install split rings (26 and 27) and chain (28).
(6) Install nipple (25) and tee (24) on gate valve (32).
(7) Install tee (24) on nipple (25).
(8) Install female coupling half (23) on tee (24).
(9) Install gasket (22) in female coupling half (23).
4-57
|