2-10
TM 10-4930-238-12&P
Three persons are required in lifting hose and component kits, which weighs 145
Ibs (64.83 kgs). Three-persons are required in lifting filter separator, which, weighs
125 Ibs (56.25 kgs). Four persons are required in lifting pump assembly which
weighs 196 Ibs (88.98 kgs). Failure to comply with this warning could result in inju-
ry to personnel.
a. Siting.
(1) Select a site that will provide a relatively level terrain.
(2) Clear away brush, leaves and dry grass from the area where the pump assembly will be operated.
b.
Installation for Two-Point Refueling Operation. (Refer to Figure 2-4.)
(1)
(2)
(3)
NOTE
Prior to starting installation procedures, remove suction hose assemblies and
ground rods from canvas container. Remove discharge hose and fittings from
frame and canvas container.
Position pumping assembly (6) in its desired location.
NOTE
Remove dust plugs and dust caps before installing individual components.
Position filter separator (7) in its desired location.
NOTE
Secure individual components with their camlock levers.
Connect elbow coupler valve (1) to drum assemblies.
Figure 2-4. FARE Schematic for Two-Point Refueling Operation.
|