TM 10-493023812&P
Table 2-4. Operators Preventive Maintenance Checks and Services - Continued
ITEM
NO.
21
22
23
24
25
26
27
28
INTERVAL
After
After
After
After
After
After
After
After
ITEM TO CHECK/
PROCEDURE
Inspect discharge and suction hose assemblies
for leaks, separation of material, cuts, missing
dust covers, damaged camlocks and loose or
missing hose clamps.
Inspect frame assembly for broken welds, bent
frame. Inspect canvas storage bag for tears or
broken straps.
Inspect closed circuit refueling nozzle for leaks.
Inspect pumping assembly for signs of oil or fuel
leaks. Notify unit maintenance.
Do not fill fuel tank while engine is running or
hot.
Check fuel tank for leaks. Notify unit mainte-
nance.
Inspect filter separator for leaks and broken
pressure indicator and water in sight glass.
Notify unit maintenance.
Inspect butterfly valve assembly for leaks and
missing dust cover. Notify unit maintenance.
Inspect tee assembly for leaks, missing dust
covers and damaged camlocks. Notify unit
maintenance.
NOT FULLY
MISSION CAPABLE IF:
Class
hose.
III leaks, damaged
Class Ill leaks.
Class Ill leaks.
Class Ill leaks.
Class Ill leaks.
Class Ill leaks.
Class Ill leaks.
Section III. OPERATION UNDER USUAL CONDITIONS
27.
ASSEMBLY AND PREPARATION FOR USE. (Refer to figures 2-4 and 2-5.)
Para.
Para.
Assembly and Preparation for Use . . . . . . . 27
Preparation for Movement . . . . . . . . . . . . . . . . . . . . . . 29
Operating Procedures . . . . . . . . . . . . . . . . . . 28
29
|