TM 10-4930-229-12&P
4-18. Wye Fitting Assembly (cont).
b. Replace.
(figure 4-12)
(1) Removal.
(a) Pull upon discharge hose camlock levers and remove two discharge hose assemblies (1).
(b) Pull upon wye fitting (2) camlock levers and remove fitting from suction hose assembly (3).
(2) Installation.
(a) Position wye fitting (2) on suction hose assembly (3) and secure by pushing down on camlock levers.
(b) Install two discharge hose assemblies (1) and secure by pushing down on camlock levers.
Figure 4-12. Wye Fitting Assembly, Removal/installation.
4-29
|