TM 10-4930-229-12&P
4-16. Adapter Assembly.
This task covers:
a. Repair
b. Replace
INITIAL SETUP
Tools:
General Safety instructions:
Tool Kit, General Mechanics, Item 1, Section Ill,
Appendix B
l
Materials/Parts:
Cleaning Solvent, Item 4, Appendix E
Rags, Wiping, Item 5, Appendix E
l
Gasket, P/N MS27030-6 (2 in.), Appendix F
Gasket, P/N MS27030-8 (3 in.), Appendix F
Gasket, P/N MS27030-9 (4 in.), Appendix F
Equipment Conditions:
FARE shutdown, para 2-12.
WARNING
Do not smoke or use an open flame in the
vicinity of the FARE, failure to comply may
result in personnel injury.
Drain any fuel into suitable container. Clean up
any fuel spills to prevent fire or environmental
hazard.
a. Repair. (figure 4-8)
(1) Disassembly.
(a) Inspect adapter assembly for leaks, damaged or missing components.
WARNING
Cleaning solvent, Federal Specification PD-680, is toxic and flammable.
Use only in a well-ventilated area. Avoid prolonged breathing of fumes.
Keep solvent away from flames. Do not use in excessive amounts.
Avoid skin contact.
(b) Clean adapter assembly with cleaning solvent and allow to dry.
(c) Disconnect hook (1) and remove dust plug (2) and gasket (3). Discard gasket.
(d) Disconnect hook (4). Remove dust cap (5) and gasket (6) from reducer (7). Discard gasket.
(2) Assembly.
(a) Install new gasket (6) and dust cap (5).
(b) Install new gasket (3) and dust plug (2).
(c) Connect hooks (1) and (4) to camlock levers on reducer (7).
4-23
|