TM 10-4930-229-12&P
4-10. Hose Assembly, Discharge (cont).
(h) Roll tool over buckle, backing off with tension handle throughout entire rolling operation.
(i) Pull cutting handle (8) to cut band.
(j) Remove tool, holding stub of band down with thumb. Clinch stub by hammering down buckle ears.
(k) Repeat steps (d) through (j); positioning band approximately 2 in. from shoulder clamp.
(2) Discharge hose. Repair a damaged discharge hose as follows:
(a) Cut hose to remove damaged section.
(b) If damaged area is within 10 feet (304.8 cm) of end of hose, remove fitting from short length of hose
and reinstall in longer section using procedure in (1), above.
(c) If damaged section is more than 10 feet (304.8 cm) from end of hose, replace with like item from
stock.
b. Replace.
(1) Removal.
(a) Pull upon camlock levers on discharge hoses and closed circuit nozzle.
(b) Remove discharge hoses from wye fitting and closed circuit nozzle.
(2) Installation.
(a) Connect discharge hoses to wye fitting and closed circuit nozzle.
(b) Push down on camlock levers to secure discharge hoses.
4-10
|