TM10-4330-235-13&P
INSTALLATION
WARNING
a.
b.
c.
d.
e.
f.
g.
h.
i.
Silicone compound, MIL-S-8660, is
toxic to skin, eyes and respiratory
tract.
Skin and eye protection
required. Good general ventilation is
normally adequate.
CAUTION
Oils from the skin can penetrate the
surface of the elements and cause
them to be ineffective. When installing
elements, do not touch the element
surface.
Open one end of bag containing a new element (11).
Apply a coating of silicone compound to the preformed
packing in the end of the element.
Insert the element (11) into the filter/separator vessel
and install it on the outlet port at the bottom of the
vessel.
Repeat steps a and b for the remaining elements, then
remove the bags from the elements.
Install a canister (10) over each element (11), engaging
the canister over the outlet port dogs (13). Press down
and turn the canister clockwise to lock it in place.
Position the band clamp (9) around the canisters (10)
and tighten clamp.
Apply a light coating of silicone compound to preformed
packing (8) and install in groove in top of vessel.
Position cover (7) on vessel and install bolts (6), flat washers (5), lock washers (4) and nuts (3). Tighten
nuts hand tight.
Refer to the instruction plate (12) on top of the cover (7) and tighten the first eight bolts (6) in the order
shown to 10 ft-lbs then tighten all bolts to 20 ft-lbs.
Close air valve (2) and drain valve (1).
4-6
|